Diketene, Inhibited Chemical Storage Specifications

Compliant storage and rental solutions for Diketene, Inhibited (C4H4O2). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Diketene, Inhibited

Diketene is used in the production of different agrochemicals such as pesticides, insecticides, and others. These agrochemicals are rigorously used in agriculture to prevent crops from weeds & pests.

Structured hazard data

Hazard class
Category 3 Flammable Liquid
Storage category
Flammable Storage
Flammable
Yes
Flash point
34 C
Storage temperature
-20 C
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
not compatible with STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE); OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); ALCOHOLS; and COMBUSTIBLES

Fire Suppression System

Dry Chemical fire suppression is recommended for Diketene, Inhibited

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Diketene, inhibited (C4H4O2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Diketene, inhibited should account for its listed hazards (Category 3 Flammable Liquid), climate control needs (-20 C), and segregation requirements. not compatible with STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE); OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); ALCOHOLS; and COMBUSTIBLES

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: a) Appearance Form: Color: yellow Form: Liquid b) Odour No data available c) Odour Threshold No data available d) pH No data available e) Melting point/freezing point No data available f) Initial boiling point and boiling range 69-70 ⁰C (156 – 158 ⁰F) at 133hPa (100 mmHg) g) Flash point 34 ⁰C (93 ⁰F) – closed cup h) Evaporation rate No data available i) Flammability (solid, gas) No data available j) Upper/lower flammability or explosive limits No data available k) Vapour pressure 10.5hPa (7.9 mmHg) at 20 ⁰C (68 ⁰F) 68 hPa (51 mmHg) at 55 ⁰C (131 ⁰F) l) Vapour density 2.9 – (Air = 1.0) m) Relative density 1.097 g/cm3 n) Water solubility No data aviable o) Partition coefficient: noctanol/ water log Pow: > 99

Matched to this chemical

Recommended storage solutions for Diketene, Inhibited

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Diketene, inhibited be stored?

Store Diketene, inhibited in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Category 3 Flammable Liquid). Climate range guidance: -20 C. Compatibility notes: not compatible with STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE); OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); ALCOHOLS; and COMBUSTIBLES US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Diketene, inhibited flammable?

Yes — Diketene, inhibited is flagged as a flammable hazard in this database (Yes). Flash point: 34 C. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Diketene, inhibited?

Diketene, inhibited is listed as: Category 3 Flammable Liquid. Confirm classification on the manufacturer SDS before designing storage.

What fire suppression is recommended for Diketene, inhibited?

Dry Chemical fire suppression is generally recommended for Diketene, inhibited (C4H4O2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Diketene, inhibited storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Diketene, inhibited. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.